• Flexible Rocoil Recoil Current Probes for Substation Scada System
  • Flexible Rocoil Recoil Current Probes for Substation Scada System
  • Flexible Rocoil Recoil Current Probes for Substation Scada System
  • Flexible Rocoil Recoil Current Probes for Substation Scada System
  • Flexible Rocoil Recoil Current Probes for Substation Scada System
  • Flexible Rocoil Recoil Current Probes for Substation Scada System

Flexible Rocoil Recoil Current Probes for Substation Scada System

Type: Rogowski
Output Signal Type: Digital Output
Production Process: SemiConductor Integrated
Material: Plastic
Accuracy Grade: 1.0G
Application: Power, Electronic, Instrument
Samples:
US$ 50/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

Contact Supplier

Diamond Member Since 2009

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
XH-RST
IP Rating
IP67
Certification
CE
Customized
Customized
Current Transformer
Flexible Rogowski Coil Current Transformer
Current Sensor
Flexible Rogowski Coil Current Sensor
Current Transducer
Flexible Rogowski Coil Current Transducer
Usage
Consumption Sensor
Output
0-0.333V AC or 0-5V AC
Accuracy
1.0
Frequency
50/60Hz
Size
Small
Color
Black
Insulation Strength
3kv
Transport Package
Cartons
Specification
ROHS, ISO9001: 2008
Trademark
Jiangyin spark
Origin
China(Mainland)
HS Code
8504
Production Capacity
200, 000 PCS/Month

Product Description

Specifications Of Flexible Rocoil Recoil Current Probes For Substation SCADA System
1.Coil length 0.2m-2m 
2.input current 100A-100KA
3. Output 0-0.333V AC or 0-5V AC or mA
4.Accuracy 1% 
 

Details Of Flexible Rocoil Recoil Current Probes For Substation SCADA System
Capable of accommodating a range of primary conductor sizes.
Characterized by high sensitivity, accuracy, linearity, minimum phase shift.
Suitable for harsh operating environments (temperature, humidity, EMI).
Current Range: 100A to 100kA
Accuracy: < 1%
Phase Shift: < 1 degrees at 50/60Hz (< 0.5 degrees typical) /li>
Linearity: ±0.2% from 10% to 100% of rated primary current
Primary Conductor Position Sensitivity: ± 2% maximum
Influence of External Field: ± 1.5% maximum
Coil Working voltage: 1000VRMS or 1000VDC
Coil Dielectric Surge Withstand: 5kVRMS for 1 minute
Operating temperature: -20ºC to +60ºC
Leads: Shielded cable, or as per customer need


Production Picture Of Flexible Rocoil Recoil Current Probes For Substation SCADA System
Flexible Rocoil Recoil Current Probes for Substation Scada System

Flexible Rocoil Recoil Current Probes for Substation Scada System

Contact Information
Flexible Rocoil Recoil Current Probes for Substation Scada System

 

Send your message to this supplier

*From:
*To:
avatar Mrs. Sindy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now