Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer

Product Details
Customization: Available
Application: Electronic, Instrument, Position Sensor, Audio, Lighting
Type: Current Transformer
Still deciding? Get samples of US$ 0/Piece
Request Sample

360° Virtual Tour

Diamond Member Since 2009

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Management System Certification
ISO 9001
OEM/ODM Availability
Yes
  • Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
  • Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
  • Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
  • Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
  • Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
  • Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
Find Similar Products

Basic Info.

Model NO.
SCT10-50A/50mA
Phase
Single
Operation Condition
Indoor
Usage
Measurement
Winding Form
Multilayer Honeycomb Type
Insulating Medium
Epoxy Resin
Installation
Active Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Capacitive Type
Model
Xh-Sct-T10(B)
Input Current
70A
Output
50mA
ID
10mm
Accuracy
0.5 ,1.0 Class
Withstanding Voltage(Hi-Pot)
3.5kv/1mA/1min
Weight
75g
Color
Black ,White ,Blue
MOQ
10 PCS
Lead Time
3-7 Days
Wire Cable
Twist ,Sheath or Others
Transport Package
Cartons
Specification
ROHS, ISO9001: 2000
Trademark
jiangyin spark
Origin
China(Mainland)
HS Code
8504
Production Capacity
30, 000 PCS/Month

Product Description

Split-Core AC Current Transformer current Sensor XH- SCT-T10(B)

φ10mm Opening With 5 To 80 Amp Rating
 

Description:

Jiangyin Spark XH-SCT-T10 Series split-core current senses AC current from 5 to 80 Amps passing through the center conductor.Split core CTs are designed for fast and easy installation.The split core design permits non-contact current measurements through magnetic field induction without requiring that the primary wire be taken offline and disconnected for CT installation.This method permits a safer,easy and portable current measurement.

SPECIFICATIONS :
1,Rated Voltage:0.66KV
2,Insulation Voltage:3500V
3,Rated Frequency:50HZ/60HZ
4,Operating Temperature:-20ºCto 70ºC
5,Weight:70g
6,Certificates:UL ,CE ,ROHS
FEATURES:
1,Small cost
2,Split core design ,Easier installation
3 Build diode ,no high voltage danager
4,Good linearity at very low current
 
Model Input(A) Max currnet(A) Output
XH-SCT-T10A 0.2-80AAC 100AAC mA/0.333VAC
/0-3VAC
XH-SCT-T10B
Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current TransformerDIMENSIONS( mm ):
Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer

Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current TransformerOther models of split core current transformer :
Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
Model I.D. Ratio Rated Amps Accuracy
XH-SCT-T06 6mm 1000:1 1, 5,10, 15, 20, 0.5 , 1.0
XH-SCT-T10 10mm 3000:1 5, 15, 30, 50, 75,80 0.5 , 1.0
XH-SCT-T16 16mm 3000:1 50, 70, 100, 120 0.5 , 1.0
XH-SCT-T24 24mm 3000:1 100, 150, 200, 300 0.5 , 1.0
XH-SCT-T36 36mm 3000:1 300, 400, 500, 600 0.5 , 1.0

Wiring and test of split core current transformer:Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer
Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current TransformerPackage of split core current transformer:
Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current TransformerShipment of split core current transformer:
Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer

Our hot sales :
Xh-Sct-T10 50A/ 50mA Sensor Clamp UL Split Core Monitoring CT Current Transformer

Note 
* We provide FREE samples for your test!
  Purchase only when you are satisfied with the FREE samples.
  
Please contact us to apply FREE Trial NOW !!

* Please let us know  model, input current ,output signal,cable leads length
* Or tell us your techincal requirement for the current transformer selection.
* OEM/ODM is welcomed. 
  

Jiangyin Spark Electronic Technology Co.,ltd
Certification: ISO9001, UL ,CE, ROSH,TUV
( Your reliable  partner for Split Core Current Transformer and Rogowski Coils. )

Address:
263 Dong wai huan road, jiangyin City, Jiangsu Province,214432, China.
Web: sparkelectronic.en.made-in-china.com


Package 
* All our CT will be well packed with bubble & white box in a Carton.
* You can design your own label and package
* Can be netural packing or OEM.


Shipping 
* Products are shipped via UPS / DHL/ FedEx / TNT, etc. (door to door), or air & sea shipment for larger qty.
* L/T: 3-7 days upon receiving payment if the qty is lower than 1000PCS and it is not customized products.
* Shipping via DHL. UPS. FedEx and TNT express usually takes 3~7days dependent on the destination country. 


Warranty 
* We provide 1 year warranty.
* If the product is defective, please notify us within 3 days after receiving. 
* All products must be returned on their original condition, in order to qualify for a refund or exchange of goods.


Our Commitment 
* Better Price than other suppliers for you because of Factory Direct Sale;
* Better Quality than before caused by our 20+ years experience about current transformer;
* Fast Delivery made by our Enthusiasm;
* Timing Reply in 24 hours all about our TEAM's Passion & Patience.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier