• DBP Split Core Current Transformer 5A Output
  • DBP Split Core Current Transformer 5A Output
  • DBP Split Core Current Transformer 5A Output
  • DBP Split Core Current Transformer 5A Output
  • DBP Split Core Current Transformer 5A Output
  • DBP Split Core Current Transformer 5A Output

DBP Split Core Current Transformer 5A Output

Type: Current Transformer
Phase: Single
Operation Condition: Indoor
Usage: Measurement
Winding Form: Single Layer & Tightly Wound Type
Insulating Medium: Epoxy Resin
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
K120*80
Installation
Busbar Type
Magnetic Circuit Structure
Combined Type
Voltage Transformation Principle
Electromagnetic Type
Transport Package
Carton
Specification
ROHS, ISO9001: 2008
Trademark
spark
Origin
China(Mainland)
HS Code
8504
Production Capacity
90, 000 PCS/Month

Product Description

The JIANGYIN SPARK  DBP series current transformer has been specially designed to facilitate their installation in new or already existing net works. They may be installed without opening any cable or bus-bar circuit.
The connection of conventional CTs usually requires the interruption of the primary side circuit to pass cables or bur-bars through the transformer core or to connect such c ables to the prima ry terminals. The DBP series transformers core may be easily opened and they may be installed and connected without any supply interruption. Thus saving time and the installation costs.
Features:

Very easy to mounting.
Wide inner window,
allowing clamping of big cables or bus-bars.
Wide range of sizes to
accommodate all the existing installations.

Specifications
Rated Current 5A to 5000A
Rated output: 5A or 1A

Rated test voltage: 3kV AC. (1 min)
Rated short-time thermal current(Ith): 60In
Rated dynamic current, (Idyn): 2.5Ith

Rated voltage,(Um): 0.72Kv AC.
Continuous overload,(Id): 1.2In
Operating temperature: -10 degree ~50 degree
Housing self-extinguishing class: VO
Safety factor: FS 5

DBP Split Core Current Transformer 5A Output
 
Ratio ID Class 0.5 Class 1 Class 3
DBP-23 100/5A 30x20 mm - - 1.5VA
DBP-23 150/5A - - 2
DBP-23 200/5A - 1.5 2.5
DBP-23 250/5A - 2.5 4
DBP-23 300/5A 1.5 2.5 6
DBP-23 400/5A 2.5 3.75 10
 
DBP-58 250/5A 80x50 mm 1 2 4
DBP-58 300/5A 1.5 3 6
DBP-58 400/5A 1.5 3 10
DBP-58 500/5A 2.5 5 15
DBP-58 600/5A 2.5 5 15
DBP-58 750/5A 3 6 20
DBP-58 800/5A 3.75 7.5 20
DBP-58 1000/5A 5 10 20
 
DBP-88 250/5A 80x80 mm 1 2 3.75
DBP-88 300/5A 1.5 3 5
DBP-88 400/5A 1.5 3 10
DBP-88 500/5A 2.5 5 15
DBP-88 600/5A 2.5 5 15
DBP-88 750/5A 3 6 20
DBP-88 800/5A 3.75 7.5 20
DBP-88 1000/5A 5 10 20
 
DBP-812 500/5A 120x80 mm - 4 12.5
DBP-812 600/5A - 5 15
DBP-812 750/5A 2.5 6 17.5
DBP-812 800/5A 3 7.5 20
DBP-812 1000/5A 5 10 20
DBP-812 1200/5A 6 12.5 25
DBP-812 1250/5A 7.5 15 30
DBP-812 1500/5A 8 17 30
 
DBP-816 1000/5A 160x80 mm 10 15 20
DBP-816 1500/5A 15 20 25
DBP-816 2000/5A 15 20 25
DBP-816 2500/5A 15 20 25
DBP-816 3000/5A 20 25 30
DBP-816 4000/5A 20 25 30
DBP-816 5000/5A 20 25 30

DBP Split Core Current Transformer 5A Output

 