• 100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor
  • 100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor
  • 100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor
  • 100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor
  • 100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor
  • 100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor

100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor

Type: Rogowski
Output Signal Type: Digital Output
Production Process: SemiConductor Integrated
Material: Metal
Accuracy Grade: 1.0G
Application: Switching Power Supply
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2009

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory

Basic Info.

Model NO.
XH-RCT, FCT
IP Rating
IP67
Certification
ISO
Customized
Customized
Item
Flexible Current Transformers Rogowski Coil
Flexible Rogowski Coil Current Sensor
Ce ,RoHS
Colour
Black ,Red ,Blue
Output
0-0.333V AC or 0-5V AC
Integrator
Rogowski Coil with Integrator or Without
Insulation Strength
3kv
Frequency
50/60Hz
Phase
Three Phase
Transport Package
Cartons with Inner Plastic Bags
Specification
ISO9001: 2000, CE, ROHS, SGS
Trademark
Jiangyin spark
Origin
China(Mainland)
HS Code
8504
Production Capacity
2000 PCS /Per Week

Product Description

Specifications Of 100A-100ka Flexible Three phase Rogowski Coil Current Transformer for Monitoring 333mv
Split Rogowski Coil current sensors are designed for fast and easy installation on existing primary conductors/ BUS bars. The split design permits non-contact AC current or current pulse measurement without requiring that the primary conductor be taken offline and disconnected for the current sensor installation. This method provides for the safe, easy and portable measurement of current.
A current sensor that is based upon the Rogowski Coil principle offers significant advantages over the standard magnetic core current transformer products. Specifically, since the sensor does not incorporate a magnetic core, magnetic core saturation (the point where incremental increases in magnetic flux are not reflected in proportional increases in secondary signal outputs) is avoided

Key specifications
 
Input current range:0-10000A
Output :Flexible Rogowski coils 0.333Vac,100mV/per 1000A,  0-5Vac
Bandwidth :1Hz-1MHz
Accuracy :≤±1%
Response time :<10ms
Auxiliary power supply :6-24VDC
Coil  length :≤2m
Status indicator :LED light
Storage  temperature range :-40ºC-70ºC
Operating temperature range :-20ºC-55ºC
Storage humidity range :10%-90% without dew
Operating humidity range :10%-90% without dew
 
Current range(AC) 100-100K A(ac)
Measure range 5% - 120% %
Power frequency 45-65 Hz
 frequency band 10 - 10KHz Hz
Rated output 0.1-5Vac, Hot sales 333mVac Vac
 Supply voltage 12 - 30V V
Power Consumption <30 mA
Offset voltage ≤3 mV
Offset drift @ -25~+70ºC               ≤±1 mV/ºC
Accuracy 1 %
Linearity 1 %FS
 Response time                              ≤20 ms
 Galvanic isolation AC,1min                       10 KV
 Isolation resistance @ DC 500V                 1000 MΩ
Operating temperature -25 to +50 ºC
Storage temperature -40 to +70 ºC
100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor


100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor

Test of Rogowski coil
100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor

Hot sales Products
100A-100ka 333mv 3 Phase Flexible Rogowski Coil Sensor

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now